TM 10-3930-664-24
C. INSPECTION
1. Inspect air restriction indicator for obvious damage.
Replace if damaged.
2. Inspect remaining components in accordance with
paragraph 1-24.
D. INSTALLATION
1. Install indicator adapter (10) into welded pipe
coupling (4). Ensure filter (11) faces coupling (4).
Install elbow (9) and connect hose assembly (8).
2. Apply loctite to threads of nine screws (6). Position
transmission top cover (5) in place and secure using
screws and washers (7).
3. Install elbow (3) into welded pipe coupling (4). Install
pipe nipple (2) into elbow.
4. Install air restriction indicator (1) onto pipe nipple (2).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
2-112
|