TM 10-3930-664-10
Location
Item
Interval
Item to
Procedure
Not Fully Mission
No.
Check/
Capable If:
Service
MAST ASSEMBLY
28
During
Sideshift Chains
With rated capacity load (4,000
Sideshift chains are not
lbs/1800 Kg) on forks, check left
properly adjusted.
and right sideshift chains for
proper adjustment.
a.
Sideshift forks to the left.
Right sideshift chain should
droop, but the upper portion of
the chain should not touch the
chain adjustment indicator. If
the upper portion of the chain
touches the chain adjustment
indicator, adjust the chains.
Refer to paragraph 3-11.
b.
Sideshift forks to the right.
Upper portion of left side chain
should just touch the chain
adjustment indicator. If the
upper portion does not touch
the chain adjustment indicator
adjust the chains. Refer to
paragraph 3-11 .
WARNING
Before raising the rails, check to
ensure that the inner rail will not
come near overhead power lines
or structures. Striking power lines
or structures could result in
equipment damage or personnel
injury.
29
During
Mainlift Chains
With forks centered, check the
Mainlift chains are not
mainlift chains for proper
properly adjusted.
adjustment.
a.
Raise forks to maximum lift
height (120 in/305 cm).
b.
Observe movement of inner
rail. Both side of inner rail
should reach full height at
same time. If top of inner rail
tilts sideways, notify
organizational maintenance
2-23
|