TM10-3930-660-34
6-7. CAB WIRING HARNESS - REPLACE/REPAIR (Contd)
9. DISCONNECT SEVEN TERMINALS (29) FROM
DEVICES INDICATED. REMOVE REAR WIRE
HARNESS SECTION (30) AND GROMMET (27).
INSPECTION
1.
CHECK CONTINUITY OF INDIVIDUAL WIRES
SUSPECTED OF BEING OPEN USING AN
OHMMETER. IDENTIFY WIRE ENDS BY THE
MARKERS.
2.
CHECK CONNECTORS (22 AND 23) FOR
LOOSE OR BROKEN PINS.
3.
CHECK GROMMETS (26 and 27) FOR TEARS
OR DETERIORATION.
4. CHECK TERMINALS AND SINGLE CONNECTORS
FOR POOR JOINTS WITH WIRE, OR OTHER
DEFECTS.
INSTALLATION
NOTE
Connect all electrical leads as tagged during removal.
1. SECURE REAR WIRE HARNESS SECTION(30)
WITH EIGHT CABLE CLAMPS (17), SIX NUTS (11),
SIX NEW LOCKWASHERS (12), FOUR NEW
LOCKWASHERS (13), AND TWO FLATWASHERS
(16). INSTALL GROMMET (27).
2.
INSERT R.H. ADJUSTABLE LIGHT WIRE
TERMINAL (29) THROUGH CAB WALL. CONNECT
TERMINAL (29) TO R.H. ADJUSTABLE LIGHT.
3.
CONNECT REMAINING SIX TERMINALS
(29) TODEVICES INDICATED.
4.
CONNECT CONNECTORS (22, 23, 24 AND 25)
TO ORIGINAL LOCATIONS. INSTALL CABLE
CLAMPS (19, 20, AND 21).
5.
INSTALL TWO GROMMETS (26) AND
GROMMET (27) TO FRONT HARNESS
SECTION (28).
6.
CONNECT ELEVEN CONNECTORS (9),
THIRTY-FOUR CONNECTORS (8), SIX
CONNECTORS (7), CONNECTORS (6),
TWENTY-SEVEN CONNECTORS (5) AND
EIGHTEEN CONNECTORS (4) TO DEVICES
INDICATED.
7.
SECURE LEADS TO HEATER STUD WITH
FLATWASHER (16), NEW LOCKWASHER AND
NUT (14).
8.
SECURE LEADS TO TWO GROUND STUDS
UNDER INSTRUMENT PANEL WITH NUTS
(11), NEW LOCKWASHERS (13),
FLATWASHERS (16), AND NEW
LOCKWASHERS (18).
9.
CONNECT FORTY-FOUR FEMALE
CONNECTORS TO MALE CONNECTORS (1).
10.
INSERT L.H. ADJUSTABLE LIGHT
CONNECTOR (2) THROUGH HOLE IN CAB
WALL AND PLUG INTO L.H. ADJUSTABLE
LIGHT. INSTALL GROMMET (26) AND FOUR
CABLE CLAMPS (17).
11.
CONNECT NEGATIVE BATTERY CABLE,
TM10-3930-660-20.
6-28
|