TM10-3930-660-34
6-4. STARTER - REPAIR (Contd)
c. Remove four screws (17 and 18) and
four brushes (19). Two brush ground
leads (20) are also attached with
screws (17).
d. Remove brushes (19) from holders
(13 and 14).
e. If necessary, remove four rivets
(21) and two supports (16). Discard
rivets (21).
NOTE
Remove field winding coil (22) only if
known to be grounded or open. If it is
being removed, use a pole spreader and a
pole shoe screwdriver.
f. Match mark all four shoes (23) and
adjacent area of field frame (8),
to ensure proper installation.
g. Remove eight screws (24), four
shoes (23) and field winding coil
(22).
7. REMOVE SOLENOID SWITCH AND RELATED
PARTS.
a. Remove two capscrews (25) and
separate cover (26) and gasket
(27) from solenoid switch housing
(28). Remove contact (29). Discard
gasket (27).
b. Remove two screws (30) and
lockwashers (31). Discard
lockwashers (31).
c. Remove solenoid switch (28), gasket
(32) and plunger return spring
(33). Discard gasket (32).
d. Remove pin (34) and plunger (35).
e. Remove screw (36), nut (37),
lockwasher (38) and shift lever
(39). Discard lockwasher (38).
6-12
|