TM 10-3930-660-24-2
HYDRAULIC JOYSTICK CONTROL VALVE MAINTENANCE - CONTINUED
0305 00
ASSEMBLY - CONTINUED
12.
Apply grease to contact surfaces of pivot bolt (5) and
mounting plate (7).
1
13.
Install pivot bolt (5) and ball (8) in mounting plate (7)
from bottom side. Use care not to dislodge ball (8).
14.
Install boot clamp (3) on mounting plate (7). Use care
2
not to tear or stretch it.
4
15.
Apply loctite to threads of capscrews (6). Install cap-
6
screws (6) and torque to 15 lb-ft (20 Nm).
3
7
5
8
409-1466
0305 00-4
|