TM 10-3930-660-24-2
HYDRAULIC JOYSTICK CONTROL VALVE MAINTENANCE - CONTINUED
0305 00
DISASSEMBLY - CONTINUED
NOTE
9
There are four identical plunger capsule
10
assemblies and four identical metering
capsule assemblies. Steps 6 thru 14 apply
11
to all four.
12
5.
Remove retaining ring (9) and cap (10).
6.
Remove O-ring (11) and seal spool (12) from cap (10).
13
Discard O-ring and seal spool.
7.
Remove retainer (13).
19
8.
Push up on spring seat (14) and remove retaining ring
18
(15).
9.
Remove spring (16), retaining ring (17) and spring
17
seat (18) from plunger (19).
14
16
15
28
409-1467
10.
Remove plug (20) from housing (28).
11.
Remove pin (21), spring seat (22) and spring (23)
from spool (24).
12.
Remove back-up ring (25) and O-rings (26 and 27)
from plug (20). Discard back-up ring and O-rings.
28
22
21
23
24
25
27
26
20
409-1468