Click here to make tpub.com your Home Page

Page Title: INSTALLATION
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-660-24-2
CRANKSHAFT MAIN BEARINGS MAINTENANCE - CONTINUED
0272 00
INSTALLATION
WARNING
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure when
drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning components. DO
NOT direct compressed air against human skin. Failure to follow this warning may cause injury or death.
Make sure air stream is directed away from user and other personnel in the area. To prevent injury, user
must wear protective goggles or face shield.
To help prevent damage to the cylinder block during main bearing bore cleaning, compressed air shall not
exceed 15 psi (103 kPa).
Cleaning compound, solvent MIL-PRF-680 Type III is an environmentally compliant and low toxic material.
However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in well-ventilated
areas. Keep away from open flames and other sources of ignition.
NOTE
If main bearings are coated with oil,
remove oil with a clean wiping rag.
1.
Clean main bearing surfaces in the cylinder block and
bearing caps with cleaning solvent. Dry surfaces thor-
oughly with low pressure compressed air, 15 psi (103
kPa) maximum.
BEARING REMOVAL/
INSTALLATION TOOL
409-931
0272 00-4

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business