TM 10-3930-660-24-2
INNER BOOM MAINTENANCE - CONTINUED
0262 00
REMOVAL - CONTINUED
21.
Carefully pull hoses (13 thru 15) from underside of hose pulley (39) out the rear of outer boom (2).
22.
Remove boom electrical cable (25) from outer boom
2
(2).
39
23.
Tie one end of a rope to anchor (37) at rear of outer
boom (2).
24.
Tie other end of rope to hose pulley support bracket
(40).
25.
Using chain, rope or hand winch, attach inner boom
37
(31) and intermediate boom (11) together at flanges.
26.
Pull inner boom (31) and intermediate boom (11) out
as an assembly until boom hose pulley (39) and rope
end are visible through hole near tensioner (20).
40
25 13 14
15
NOTE
2
11
Leave rope tied to cable.
31
27.
Untie rope from hose pulley support bracket (40). Tie
same rope end to plug end of boom electrical cable
(25).
28.
Pull rope from rear of outer boom until cable (25) is
not looped inside outer boom (2).
2
20
409-1408
CAUTION
To prevent damage to hoses and boom electrical cable, have assistant guide hoses out rear of outer boom
during step 29.
29.
Use hoist and sling (or other suitable lifting device) to push intermediate boom (11) and inner boom (31) as an assembly
into outer boom (2) until intermediate boom extends approximately 1 ft (0.3 m) from outer boom (2).
0262 00-6
|