TM 10-3930-660-24-2
ELECTRIC JOYSTICK MAINTENANCE - CONTINUED
0235 00
TESTING AND ADJUSTMENT OF JOYSTICK "THRESHOLD" AND "MAX OUT" SETTINGS - CONTINUED
NOTE
During step 43 turn max out control counterclockwise to lower ammeter reading and clockwise to raise
ammeter reading.
43.
If reading in step 42 was not within limits of 600 to
640 mA, adjust max out control (34) and repeat step
42 until ammeter reads approximately 620 mA.
32 33
36
34
409-1133
44.
Turn starter switch off (TM 10-3930-660-10).
45.
Disconnect leads of ammeter. Secure electrical lead no. 56 to terminal B of bottom circuit board (22) with screw (35).
46.
Repeat steps 25 thru 45 and check that current readings are still within limits. Readjust threshold (33) and max out (34)
controls as required.
47.
Secure plate (24) with four capscrews (23).
35
31
22
23
24
409-1129
409-1134
48.
Operate joystick and check for proper operation (TM 10-3930-660-10).
END OF WORK PACKAGE