TM 10-3930-660-24-2
MAIN WIRING HARNESS REPLACEMENT - CONTINUED
0232 00
REMOVAL
NOTE
Tag all electrical connections before removing for use during installation.
1.
Unplug 25 male connectors (1), three spade terminals (2) and female receptacle (3) from devices indicated.
2.
Disconnect four terminal rings (4), two terminal rings (5), eight terminal rings (6), terminal ring (7), twelve terminal
rings (8), terminal ring (9), terminal ring (10), terminal ring (24) and terminal ring (11) from devices indicated.
3.
To disconnect ground terminal rings (6 and 7), remove five nuts (12), five lockwashers (13) and five flatwashers (14).
Discard lockwashers.
4.
Remove four capscrews (15), nuts (16), lockwashers (17) and cable clamps (18). Discard lockwashers.
5.
Carefully push out four grommets (19).