TM 10-3930-660-24-2
FUEL SHUTOFF SOLENOID REPLACEMENT (152 HP) - CONTINUED
0226 00
REMOVAL
1.
Clean fuel shut-off solenoid (1) and surrounding area
of pump to prevent entry of contaminants into valve.
2.
Disconnect electrical wires (2) from shut-off solenoid
(1).
2
1
409-1071
3.
Remove shut-off solenoid (1), using care not to drop
6
plunger (3) and spring (4).
7
4.
Remove O-ring (5), nut (6), lockwasher (7) and spade
5
terminal (8). Discard O-ring and lockwasher.
1
8
4
3
409-1072
NOTE
Discard entire shut-off solenoid assembly, which includes plunger and spring, if shut-off solenoid is defective.
INSTALLATION
1.
Install new O-ring (5), spade terminal (8), new lockwasher (7) and nut (6) on shut-off solenoid (1).
2.
Place plunger (3) and spring (4) in position in shut-off solenoid bore.
3.
Install shut-off solenoid (1), making certain that plunger (3) and spring (4) remain properly assembled to solenoid (1)
during installation.
4.
Connect electrical lead (2) to shut-off solenoid (1).
5.
Connect battery cables (WP 0107 00).
6.
Operate engine and check for proper operation and leaks (TM 10-3930-660-10).
END OF WORK PACKAGE
0226 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |