TM 10-3930-660-24-1
PISTON PUMP REPLACEMENT - CONTINUED
0174 00
INSTALLATION - CONTINUED
CAUTION
Piston pump must be purged of air before engine is started. Refer to WP 0174 00. Failure to purge air as
directed may result in severe damage to piston pump.
12.
Purge air from the piston pump (WP 0174 00).
13.
Remove supporting material from boom.
14.
Install transmission cover (WP 0150 00).
END OF WORK PACKAGE