TM 10-3930-660-24-1
EMERGENCY STEERING PUMP REPLACEMENT - CONTINUED
0139 00
REMOVAL - CONTINUED
1.
Disconnect power cable (1) and negative cable (2)
from pump (4).
2.
Disconnect electrical lead (3) from relay (5).
4
5
3
2
1
409-542
NOTE
Hose is connected directly to hydraulic reservoir. When disconnecting any hose directly connected to reser-
voir at pump end, hose must be elevated, plugged and tied in an up position above the level of fluid in the
reservoir.
3.
Disconnect and plug hoses (6 and 7) from tee (8).
4.
Disconnect and plug hose (9) from adapter (10).
5.
Disconnect and plug hoses (11 and 12) from tee (13) and adapter (14).
0139 00-2
|