TM 10-3930-660-24-1
BOOM ELECTRICAL JUNCTION BOX ASSEMBLY REPLACEMENT - CONTINUED
0085 00
REMOVAL - CONTINUED
14.
Remove eight electrical cables (26) from MLRS con-
trol valve (27) at plugs (28).
28
28
26
26
27
409-332
15.
Remove four nuts (29), four lockwashers (30) and remove boom electrical junction box assembly (1) from MLRS
attachment frame (25). Discard lockwashers.
INSTALLATION
1.
Position boom electrical junction box assembly (1) on
MLRS attachment frame (25) and secure with four
new lockwashers (30) and four nuts (29).
2.
Connect eight electrical cables (26) to MLRS control
valve (27) at plugs (28).
25
30
29
409-333
1
0085 00-4
|