STARTING MOTOR REPLACEMENT (165 HP) - CONTINUED
0065 00
REMOVAL - CONTINUED
CAUTION
Support starting motor to prevent from dropping during removal.
7.
Use assistance to remove remaining screw (28) and
28
starting motor (3) with starting motor solenoid (19)
from bell housing (4) as an assembly.
4
19
3
409-1785 02
TR003
INSTALLATION
CAUTION
Support starting motor to prevent it from dropping during installation.
1.
Use assistance to install starting motor (3) with starting motor solenoid (19) on bell housing (4) with screw (28). Torque
screw to 32 lb-ft (43 Nm).
2.
Install two electrical wires (26 and 27) on starting motor solenoid (19) with washer (25) and nut (24).
3.
Install two electrical wires (22 and 23) on starting motor solenoid (19) with lockwasher (21) and nut (20).
4.
Install two electrical wires (17 and 18) and positive cable (16) on starting motor solenoid (19) with starwasher (15) and
nut (14).
5.
Install electrical wire (12) on auxiliary positive cable (13) with screw (11) and nut (10). Torque screw to 32 lb-ft (43
Nm).
0065 00-3