TM 10-3930-660-24-1
FUEL SHUTOFF SOLENOID TESTING (152 HP) - CONTINUED
0020 00
TESTING
NOTE
Be sure starter switch is in OFF position during step 1.
Electrical leads are connected together with a jumper strap. Do not remove jumper strap when disconnecting
electrical leads for this test.
1.
Disconnect female spade connectors of two electrical
leads R and 07 (1) from male spade connector of sole-
noid (2).
2.
Place one probe of ohmmeter at terminal (A) of sole-
noid (2). Place other probe of ohmmeter at engine
ground.
NOTE
Ohmmeter should read 29.5 ohms +/- 2.5 ohms
during test in step 3. If ohms reading is not
within acceptable limits, solenoid requires
replacement (WP 0226 00).
3.
Connect female spade connectors of two electrical
leads R and 07 (1) to male spade connector of solenoid
(2).
NOTE
Be sure auxiliary fuel shutoff switch is in the
1
ON position during step 5.
4.
Test current draw of fuel shutoff solenoid.
5.
Position clamps of ammeter around electrical leads
A
(1).
NOTE
Ammeter should read approximately one
ampere when starter switch is turned to the ON
2
position. If reading is not correct, solenoid
requires replacement (WP 0226 00).
409-156
6.
Have an assistant turn engine start switch to the ON
position without starting the engine.
END OF WORK PACKAGE