UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0011 00
Table 1. Unit Preventive Maintenance Checks and Services (PMCS) for 6K Forklift - Continued.
Location
Item To
Man-
Check/
Hours
Item No.
Interval
Procedure
Service
g. Remove batteries (WP 0106 00).
16
Semi-
Batteries
(Con't) annual
h. Remove filler caps and check electrolyte level in battery cells. Electro-
lyte level should be to bottom of filler openings. Add distilled water as
required and reinstall filler caps snugly.
i. As required, use a baking soda solution of 4 oz of baking soda with 1 qt
(0.95 l) of clean water to remove any acid film from batteries. Rinse with
clean water. Reinstall batteries (WP 0106 00).
j. Clean battery terminals with a fine grade of sandpaper or emery cloth
(Item 12, WP 0323 00).
k. Connect battery cables (WP 0107 00). Coat terminal connections with
petroleum jelly (Item 22, WP 0323 00).
0011 00-7