g. Remove batteries (WP 0106 00).
16
Semi-
Batteries
(Con't) annual
h. Remove filler caps and check electrolyte level in battery cells. Electro-
lyte level should be to bottom of filler openings. Add distilled water as
required and reinstall filler caps snugly.
i. As required, use a baking soda solution of 4 oz of baking soda with 1 qt
(0.95 l) of clean water to remove any acid film from batteries. Rinse with
clean water. Reinstall batteries (WP 0106 00).
j. Clean battery terminals with a fine grade of sandpaper or emery cloth
(Item 12, WP 0323 00).
k. Connect battery cables (WP 0107 00). Coat terminal connections with
petroleum jelly (Item 22, WP 0323 00).