TM10-3930-660-20
Pints (Liters) of
Ethylene Coolant
Lowest Expected
Inhibited Glycol
Solution Specific
Ambient Temperature
Per Gal. (Liters)
Compound, Antifreeze
Gravity at 68° F
F (C)
of Coolant
Arctic
(20° c)
+20 (+7)
1.5 (0.71)
Issued full strength and
1.022
+10 (-12)
2.0 (0.95)
ready mixed for O to 45°F
O (-18)
1.038
2.75 (1.30)
(-18 to -54 C) tem-
1.047
-10 (-23)
3.25 (1.54)
peratures for both initial
1.055
-20 (-29)
3.50 (1.88)
installation and replenish-
1.082
-30 (-34)
4.0 (1.90)
ment of losses. DO NOT
1.073
-40 (-40)
4.25 (2.01 )
DILUTE WITH WATER OR
-50 (-46)
Arctic antifreeze
ANY OTHER SUBSTANCE.
-60 (-51)
preferred
-75 (-80)
Table 20-1.
Freezing Points, Composition, and Specific Gravities of Military
Antifreeze Materials.
1. Ensure that the cab skylight guard is positioned over the cab skylight
and latched.
m. Ensure that the engine access doors are closed and latched.
n. Fill-in DD Form 1397 completely and attach to a conspicuous part of the
vehicle.
20-2.
PREPARATION FOR LONG-TERM STORAGE
a. Perform the operator preventive maintenance checks and services (PMCS)
contained in TM10-3930-660-10.
b. Perform the organizational preventive maintenance checks and services (PMCS)
contained in table 2-1 of chapter 2.
c. Perform the lubrication contained in lubrication order LO10-3930-660-12.
d. Thoroughly clean the vehicle.
Use touch-up paint where necessary to prevent
rust.
e. Coat all exposed areas of the cylinder rods with grease to protect polished
surfaces.
If the vehicle has accumulated very low miles since the last scheduled lubrication
service, do not drain and refill the transmission or axles (skip step f).
f. Drain and refill the transmission and axles with new oil.
g. Schedule the next preventive maintenance checks and services (PMCS) on DD Form
314*
20-2
|