TM10-3930-660-20
18-22.
BOOM HOSE PULLEY- REPLACE (Contd)
5.
6.
7.
8.
CONNECT BOOM ELECTRICAL CABLE (4)
AT PLUG (9A).
INSTALL FOUR CLAMP ASSEMBLIES (6) TO
SECURE BOOM ELECTRICAL CABLE (4) TO
UNDERSIDE OF BOOM.
CONNECT THREE HYDRAULIC HOSES (3) AT
FITTINGS (5) BEHIND TENSIONER (2).
CONNECT NEGATIVE BATTERY CABLE, PARA.
8-44.
CAUTION
Always check adjustment of chains, boom
electrical cable, and boom hoses
whenever boom hose pulley is replaced.
Refer to para. 18-24 and 18-25. Failure
to follow this instruction will result
in damage to boom electrical cable or
hydraulic hoses.
9. CHECK/ADJUST CHAIN ADJUSTMENT, PARA.
18-24.
10. CHECK/ADJUST TENSION OF HYDRAULIC
HOSES AND BOOM ELECTRICAL CABLE,
PARA. 18-25.
18-89
|