TM10-3930-660-20
18-19.
MLRS ATTACHMENT - REPLACE (Contd)
Wipe the area clean around all hydraulic
connections to be opened during removal
and disassembly.
Cap oil lines and plug
holes after removing lines.
Contamination of the hydraulic system
could result in premature failure.
Use
metal caps when specified.
If more than one hydraulic line is to be
removed, identify lines to assure proper
installation.
Use suitable container to
catch any hydraulic oil that may drain
from system.
Remove caps and plugs as hoses are
installed.
Wipe all sealing surfaces on
hydraulic components and hoses clean and
dry.
Apply film of clean hydraulic oil
to all seals as they are installed.
REMOVAL
1. DISCONNECT BOOM ELECTRICAL CABLE LEADS
(1) AT JUNCTION BOX (2) AND REMOVE
BOOM ELECTRICAL CABLE (3).
a. Loosen four screws (4) and
separate cover (5) from box (2).
Only disconnect electrical leads of boom
electrical cable (3) during steps lb
through ld.
Do not disconnect any other
electrical leads inside box during these
steps.
Tag screw terminals on terminal strips
as electrical leads are removed for use
during installation. Note that terminals
on strips (6) and (7) are not marked.