TM10-3930-660-20
18-8.
PRIORITY VALVE - REPLACE (Contd)
4. REMOVE PRIORITY VALVE (4).
5. IF NECESSARY, REMOVE HYDRAULIC BYPASS
SWITCH (1) FROM PRIORITY VALVE (4),
PARA. 8-51.
INSTALLATION
Remove caps and plugs as hoses are
installed. Wipe all sealing surfaces on
valve and hoses clean and dry.
1. IF REMOVED, INSTALL HYDRAULIC BYPASS
SWITCH (1) TO VALVE (4),
2. SECURE PRIORITY VALVE (4
MOUNTING HARDWARE.
a. Position valve (4) on
bracket.
b. Install two bolts (7)
PARA. 8-51.
WITH
mounting
through holes
(8) on mounting bracket and push
bolts through valve body.
c. Place a new lockwasher (6) on end
of each bolt (7).
Apply Loctite 242 to bolts (7) as nuts
(5) are installed.
d. Place a nut (5) on end of each
bolt (7).
Tighten both nuts (5)
to secure valve.
3. CONNECT SIX HYDRAULIC LINES (2) AT
FITTINGS (3) OF PRIORITY VALVE (4).
4. CONNECT ELECTRICAL LEADS AT HYDRAULIC
BYPASS SWITCH (1).
a. Connect electrical lead 10 to
terminal C of switch (1).
b. Connect electrical lead 91 to
terminal NC of switch (1).
18-36
|