TM10-3930-660-20
Table 2-2.
Electrical Troubleshooting (Contd)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
MLRS ATTACHMENT GROUP
18. ONE OR MORE FORK, CARRIAGE, OR ATTACHMENT FUNCTIONS NOT WORKING
Step 1. Check for defective electrical joystick controller.
Test and, if necessary, replace electric joystick assembly, para. 8-19.
Step 2. Check for shorted or damaged connector plug(s) on joystick harness
and boom electrical cable bulkhead connector at rear of boom, and
for broken or damaged wire(s) and/or loose connections.
Check connections and wires for continuity.
Check continuity between
the electric joystick and MLRS valve.
Refer to electrical schematic,
page F/O-2 and paragraphs 8-46 and 8-48.
Replace wires as necessary, para. 8-46 and 8-48.
19. FORKS WILL NOT AUTOLEVEL
Step 1. Check that fork autoleveler switch is on.
Move control to ON position, see TM1O-393O-66O-1O.
Step 2. Check fork autoleveler switch for defects.
Replace fork autoleveler switch if defective, para. 8-21.
Step 3. Check for damaged or broken wire(s) from toggle switch to
fork autoleveler switch.
Repair or replace wire(s) as necessary, para. 8-46 and 8-47.
Step 4. Check for defective fork autoleveler switch or circuit board.
Test fork autoleveler switch or circuit board and replace if defective,
para. 8-20 and 8-21.
2-21
|