TM10-3930-660-20
18-5.
PISTON PUMP - TEST/REPLACE (Contd)
g. Tag, disconnect, and plug the load
compensator line (5) at the load
compensator (6) .
h. Connect a test hose from the tee
fitting on the inlet port of the
flowmeter to the load compensator
(6) .
3. CHECK THAT THE TEST CONNECTIONS MATCH
THOSE SHOWN ON THE TEST SCHEMATIC IN
THIS PARAGRAPH.
4. CHECK FOR PROPER FLOW.
a. Start and run the engine at full
throttle, TM10-3930-660-10.
b. Adjust the flowmeter to 2500 psi.
To ensure accurate flow readings, the
flowmeter should be installed as close
as possible in the hydraulic circuit to
the pump (2), and with as few
connections as possible.
c. The flow should be within 20 to 26
gpm.
If the flow is less than 20
gpm, replace hydraulic pump (2).
Refer to removal and installation
sections of this paragraph for
pump replacement instructions.
d. Stop engine, TM10-3930-660-10.
5. REMOVE FLOWMETER.
After testing is completed, remove
the hydraulic flowmeter, test
hoses, and test tee. Connect
hydraulic hoses (1) and (3) to
pump (2) as tagged.
CAUTION
Piston pump must be purged of air before
engine is started. Refer to para. 18-3
for purging instructions. Failure to
purge air as directed may result in
severe damage to piston pump.
6. PURGE AIR FROM THE PISTON PUMP.
PARA. 18-3.
7. INSTALL TRANSMISSION COVER,
PARA. 16-6.
18-16
|