TM10-3930-660-2O
18-5.
PISTON PUMP - TEST/REPLACE (Contd)
WARNING
When working under the boom always use
blocks or other supports. Combined
weight of boom and MLRS attachment is
approximately 6300 pounds. Failure to
adequately support the boom could result
in severe injury or death.
CAUTION
Wipe the area clean around all hydraulic
connections to be opened during removal
and disassembly. Cap oil lines and plug
holes after removing lines.
Contamination of the hydraulic system
could result in premature failure.
If more than one hydraulic line is to be
removed, identify lines to assure proper
installation.
Use suitable container to
catch any hydraulic oil that may drain
from system.
At operating temperatures, hydraulic oil
is hot and under pressure.
Hot oil can
cause injuries.
Allow hydraulic oil to
cool before disconnecting any hydraulic
lines.
REMOVAL
1. DISCONNECT HYDRAULIC HOSES.
a. Tag and disconnect hose (1) and
hose (2), from tee (3). Leave tee
(3) and reducer (4) assembled to
pump (5).
b. Tag and disconnect hoses (6) and
(7) from two reducers (8). Leave
tee (9) and reducers (8)
assembled to pump (5).
18-12
|