TM10-3930-660-20
18-3.
HYDRAULIC SYSTEM - SERVICE (Contd)
C. Place auxiliary fuel shut-off
switch in the off position,
TM10-3930-660-10.
A solid stream will flow out of both
loosened hoses (6) and (8) when air is
purged from pump (l).
d. Crank engine until solid stream of
fluid is flowing from both hoses
(6) and (8). While continuing to
crank engine, have assistant
tighten hoses (6) and (8).
e. Stop cranking engine. Place
auxiliary fuel shut-off switch in
the ON position,
TM10-3930-660-10.
If pump (5) will not pump oil after
purging, further troubleshooting is
required, para. 2-12.
2. CHECK HYDRAULIC OIL LEVEL, FILL
HYDRAULIC RESERVOIR AS REQUIRED, AND
CHECK FOR LEAKS, LO10-3930-660-12.
18-5
|