TM10-3930-660-20
Table 2-2.
Electrical Troubleshooting (Contd)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
BATTERY SYSTEM
13. Low BATTERY OUTPUT
Step 1. Check for low electrolyte level in battery.
Add distilled water to battery.
Charge battery, para. 8-43 and
TM9-6140-200-14.
Step 2. Check for loose or corroded battery cables.
Clean and tighten cables, para. 8-44.
Step 3. Check for bad or weak cell in battery.
Test battery using a hydrometer.
Refer to TM9-6140-200-14.
CAB GROUP
14. BOTH FRONT AND REAR WIPERS AND WASHER DO NOT WORK
Step 1. Check if circuit breaker (CB3) is tripped.
l The circuit breakers will trip if there is a shorted or grounded wire.
l The circuit breakers will automatically reset after cooling. They
cannot be reset manually.
l Under normal operating conditions, circuit breakers should never
require replacement. However, if a circuit breaker does not reset
after it has cooled, the circuit breaker is defective and must be
replaced, para. 8-12.
Check circuit for shorts, bad ground, or defective electrical
components.
Refer to the electrical schematic, page F/O-l. Replace
defective component, para. 7-3, 7-4, and 7-5.
Step 2. Check for faulty wiring in circuit.
Check for poor ground connections. Refer to electrical schematic, page
F/O-l .
Check for broken wires and loose connections, para. 8-46.
2-19
|