TM10-3930-660-20
Table 2-2.
Electrical Troubleshooting (Contd)
MALFUCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 2.
Step 3.
Step 4.
Check if circuit breaker (CB7) is tripped.
l The circuit breakers will trip if there is a shorted or grounded wire.
l The circuit breakers will automatically reset after cooling. They
cannot be reset manually.
l Under normal operating conditions, circuit breakers should never
require replacement. However, if a circuit breaker does not reset
after it has cooled, the circuit breaker is defective and must be
replaced, para. 8-12.
Check circuit for shorts, broken wire, or bad ground.
Refer to
electrical schematic, page F/O-l.
Check for bad ground connection, broken wire, loose connections,
or faulty floodlight assembly.
Test floodlight assembly and wires for continuity, para. 8-46 and
8-47. Replace if defective.
Check for defective light switches.
Test for continuity in boom, front, and rear, floodlight switches.
Replace switches if defective, para. 8-8.
WARNING SYSTEMS
11. HORN DOES NOT SOUND
Step 1. Check if circuit breaker (CB10) is tripped.
l The circuit breakers will trip if there is a shorted or grounded wire.
l The circuit breakers will automatically reset after cooling. They
cannot be reset manually.
l Under normal operating conditions, circuit breakers should never
require replacement. However, if a circuit breaker does not reset
after it has cooled, the circuit breaker is defective and must be
replaced, para. 8-12.
Test circuit for shorts, broken wire or bad ground. Refer to electrical
schematic, page F/0-l.
2-17
|