Table 2-2.
Electrical Troubleshooting (Contd)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 4. Check for defective gauge, defective fuel level sender, or fuel saturated
float.
Replace gauge and/or fuel level sender if necessary, para. 8-7 and 8-39.
LIGHTING SYSTEM
8. BLACKOUT LIGHTS DO NOT WORK
Check for tripped circuit breaker (CB4), faulty switch, faulty
wiring, or faulty circuit breaker (CB4).
l The circuit breakers will trip if there is a shorted or grounded wire.
l The circuit breakers will automatically reset after cooling. They
cannot be reset manually.
l Under normal operating conditions, circuit breakers should never
require replacement. However, if a circuit breaker does not reset
after it has cooled, the circuit breaker is defective and must be
replaced, para. 8-12.
Check circuit for shorts and bad grounds. Refer to the electrical
schematic, page F/O-1.
Replace defective electrical components as required, para. 8-12, 8-14,
8-33, and 8-34.
9. FLOODLIGHTS, HORN, AND BACKUP ALARM OPERATE IN BLACKOUT MODE.
Check for defective blackout light relay (RY2).
Test and, if necessary, replace blackout light relay (RY2), para. 8-24.
10. FLOODLIGHT(s) DO NOT WORK
Step 1. Check that floodlight bulbs have not failed.
Replace bulbs if necessary, para. 8-32.
2-16
|