TM10-3930-660-20
Table 2-2.
Electrical Troubleshooting (Contd)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Check circuit for shorts, bad ground, or defective electrical
components.
Refer to the electrical schematic, page F/O-l.
Step 2. Check for defective starter relay.
Check if starter relay closes.
If not, replace starter relay, para.
8-22.
Step 1. Check continuity of gauge wiring harness, para. 8-46.
Replace broken wires or tighten loose connections, para. 8-46.
Step 2. Check for poor ground connection.
Check for poor ground connection at sender.
Step 3. Check for grounding of wire between gauge and sender.
Inspect wire between gauge and sender for grounding. Refer to
electrical schematic, page F/O-l.
Step 4. Check gauge and sender for defects.
Replace gauge and/or sender if defective, para. 8-3, and 8-36 through
8-39.
7. FUEL GAUGE AND LEVEL GAUGE DO NOT WORK OR GIVE INACCURATE FUEL LEVEL READINGS
Step 1. Check continuity of gauge wiring harness, para. 8-46.
Replace broken wires or tighten loose connectional para. 8-46.
Step 2. Check for poor ground connection.
Make sure circuit has good ground connection at the sender. Refer to
electrical schematic, page F/O-l.
Step 3. Check for grounding of wire between gauge and fuel level sender.
Inspect wire between fuel level sender and gauge for grounding. Refer
to electrical schematic, page F\O-l.
2-15
|