TM10-3930-660-20
14-6.
EMERGENCY STEERING PUMP - REPLACE (Cont'd)
CAUTION
Wipe the area clean around all hydraulic
connections to be opened during removal
and disassembly.
Cap oil lines and plug
holes after removing lines.
Contamination of the hydraulic system
could result in premature failure.
WARNING
At operating temperatures, hydraulic oil
is hot and under pressure.
Hot oil can
cause injuries.
Allow hydraulic oil to
cool before disconnecting any hydraulic
lines.
If more than one hydraulic line is to be
removed, identify lines to assure proper
installation.
Use suitable container to
catch any hydraulic oil that may drain
from system.
1. TAG AND DISCONNECT ELECTRICAL LEADS
AND CABLES (1), (2), AND (3), AT PUMP
(4) AND RELAY (5).
a. Tag and disconnect
and negative cable
(4) .
b. Tag and disconnect
power cable (1)
(2) from pump
electrical lead
(3) from relay (5).
Hose (7) is connected directly to
hydraulic reservoir. When disconnecting
any hose directly connected to reservoir
at pump end, hose must be elevated,
plugged, and tied in an up position above
the level of fluid in the reservoir.
14-8
|