Record all deficiencies and shortcomings, along
taken, on DA Form 2404. The Item Number column
numbers used on the TM Number column on DA Form
TM10-3930-660-20
with the corrective action
is the source for the
2404.
2-7.
ORGANIZATIONAL PREVENTWE MAINTENANCE CHECKS AND SERVICES
a.
The item numbers of the table indicate the sequence of PMCS.
Perform at
intervals shown below:
a. Do your (Q) PREVENTIVE MAINTENANCE quarterly (every three months).
b. Do your (S) PREVENTIVE MAINTENANCE semiannually (every six months).
c. Do your (A) PREVENTIVE MAINTENANCE annually (once every year).
b.
If something doesnt work, troubleshoot it according to the
instructions in this manual or notify your supervisor.
c. Always do your preventive maintenance in the same order, so it gets
to be a habit.
Once youve had some practice, youll spot anything
wrong in a hurry.
d.
If anything looks wrong and you cant fix it, write it down on your DA Form
2404.
If you find something seriously wrong, report it to Direct Support
Maintenance as soon as possible.
Dry cleaning solvent P-D-680 is toxic and flammable.
Wear protective goggles and gloves and use only in
well ventilated area.
Avoid contact with skin, eyes
and clothes and dont breathe vapors.
Do not use
near open flame or excessive heat.
The flash point
is 100 TO TF-138 To TF (38 To TC-50 To TF).
If you
become dizzy while using cleaning solvent, get fresh
air immediately and get medical aid.
If contact
with eyes is made, wash your eyes with water and get
medical aid immediately.
Compressed air, used for cleaning purposes will not
exceed 30 psi.
Use only with effective chip guarding
and personnel protective equipment (goggles/shield/
gloves, etc.)
(1)
Keep it clean:
Dirt, grease, oil and debris only get in the way and may
cover up a serious problem.
Clean as you work and as needed.
Use dry
cleaning solvent (P-D-680) to clean metal surfaces.
Use soap and water
when you clean rubber or plastic material.
2-3
|