TM10-3930-660-20
8-48.
BOOM ELECTRICAL CABLE - TEST/REPLACE/REPAIR (Cent d)
INSTALLATION
1.
INSTALL ELECTRICAL CABLE (12 ) INSIDE
BOOM .
a.
b.
Untie rope end from hose tensioner
(21) and tie rope end to cable
(12) .
Cover knot area with
electrical tape to prevent knot
from snagging inside boom.
Have an assistant feed cable (12)
through access hole (a) at hose
tensioner (21). Pull rope from
rear of boom until cable appears.
Guide cable (12) over pulley (36) at
rear of boom before pulling cable (12)
tight in STEP 1c.
Be sure cable is
properly positioned in sheave of pulley
(36).
Be sure cable (12) is positioned through
sleeve
c.
d.
(35) inside boom during STEP c.
Have an assistant feed cable (12)
through hole at rear of boom.
Carefully pull rope at front of
boom until cable (12) appears.
Untie rope at front of boom from
cable (12) and MLRS attachment.
2.
SECURE CLAMP (18) AND CABLE (12) To
UNDERSIDE OF MLRS ATTACHMENT WITH
FLATWASHER (17), NEW LOCKWASHER (16)
AND NUT (15).
8-149
|