TM10-3930-660-20
8-44. BATTERY CABLES AND TERMINALS - SERVICE/REPLACE (Contd)
3. POSITION NEGATIVE BATTERY CABLE (4)
IN BATTERY BOX (3) AND CONNECT CABLE
(4) AT STE/ICE SHUNT (37).
a. Position negative battery cable
(4) inside battery box (3).
b. Position short end of negative
battery cable (4) on terminal (40)
of STE/ICE shunt (37) and secure
with capscrew (38) and new
lockwasher (39).
4. INSTALL POSITIVE EMERGENCY STEER PUMP
POWER CABLE (29), POSITIVE BATTERY
CABLE (11), AND NEGATIVE BATTERY
CABLE (4), AT SLAVE RECEPTACLE (30).
a.
b.
c.
d.
Position negative battery cable
(4) on negative terminal (36) of
slave receptacle (30).
Secure cable (4) to terminal (36)
with capscrew (34) and new
starwasher (35).
Position positive emergency steer
Pump power cable (29) and positive
battery cable (11) on positive
terminal (33) of slave receptacle
(30) .
Secure cables (29) and (11) with
capscrew (31) and new starwasher
(32) .
8-121
|