TM10-3930-660-20 8-39. FUEL LEVEL SENDER -  TEST/REPLACE  (Cont’d) 2. SECURE LEAD (7) WITH NUT (5) AND NEW LOCKWASHER (6). 3. SECURE SENDER (4) AND CAP (3) WITH FIVE CAPSCREWS (1) AND FIVE NEW LOCKWASHERS (2). 4. CONNECT NEGATIVE BATTERY CABLE, PARA.  8-44. TESTING 1. 2. 3. REMOVE THE SENDER (4). SEE REMOVAL IN THIS PARAGRAPH. TEST THE SENDER (4). a. b. c. d. Connect one ohmmeter lead to the sender terminal (a) and the other lead to the metal flange of the  sender  (b). Move the float (c) up and down while observing the ohmmeter. Resistance  should  change  from approximately 30 to 240 ohms. Replace sender (4) if the resistance is not within specifications. INSTALL THE SENDER (4). SEE INSTALLATION SECTION OF THIS PARAGRAPH. 8-100

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business