| |
TM10-3930-660-20
8-23. EMERGENCY STEER PUMP RELAY (PUMPMOUNTED - TEST/RBPLACE (Cont'd)
3. REMOVE TWO NuTS (5), TWO LOCKWASHERS
(6), AND TWO SCREWS (7) SECURING CLAMP
(8) AND RELAY (2) TO EMERGENCY STEER
PUMP .
DISCARD LOCKWASHERS (6).
4. REMOVE CLAMP (8) AND RELAY (2) FROM
PUMP AS AN ASSEMBLY.
INSTALLATION
1. POSITION CLAMP (8) AND RELAY (2) ON
EMERGENCY STEER PUMP AS AN ASSEMBLY.
2. SECURE CLAMP (8) AND RELAY (2) TO
EMERGENCY STEER PUMP WITH TWO NUTS
(5), TWO NEW LOCKWASHERS (6), AND
Two SCREWS (7) l
3. CONNECT ELECTRICAL LEADS AND CABLES
(1) TO RELAY (2) AND SECURE WITH FOUR
NEW LOCKWASHERS (4) AND FOUR NUTS
(3).
4. CONNECT NEGATIVE BATTERY CABLE,
PARA. 8-44.
8-60
|