TM10-3930-660-20 8-10. WARNING  LIGHTS   - REPLACE (Cont’d) c. Slide warning light socket (2) out through mounting hole on instrument  panel  (6). INSTALLATION 1. INSTALL WARNING LIGHT SOCKET (2) AND WARNING LIGHT LENS/BULB ASSEMBLY (5) TO INSTRUMENT PANEL (6). a. Slide warning light socket (2) in through mounting hole on instrument panel (6). b. Secure warning light socket (2) with nut (7) at face of instrument panel  (6). c. Screw warning light lens/bulb assembly (5) into warning light socket (2) at face of instument panel  (6). 2. INSTALL THREE ELECTRICAL LEADS (1) TO WARNING LIGHT SOCKET (2). Push three female connectors (3) of wire leads (1) on three male terminals (4) of warning light socket (2) as tagged. 3. INSTALL INSTRUMENT PANEL(S), PARA.  8-6. 4. CONNECT NEGATIVE BATTERY CABLE, PARA.  8-44. 8-24