TM10-3930-660-20 8-8. TOGGLE AND PUSHBUTTON  SWITCHES -  REPLACE  (Cont’d) 2.   REMOVE SWITCH (2) FROM INSTRUMENT PANEL (7). a. For pushbutton switches, remove nut and rubber cover assembly (8) from switch (2) at face of instrument panel  (7). b. Slide switch (2) out of mounting hole on instrument panel (7). Note orientation of toggle switches for use during installation. c. For toggle switches, remove nut (9) from switch (2) at face of instrument  panel  (7). d. Slide switch (2) out of mounting hole on instrument panel (7). INSTALIATION 1. INSTALL SWITCH (2) TO INSTRUMENT PANEL  (7). NOTE Position toggle switches as noted during removal. a. b. c* d. Slide switch (2) in through mounting hole on instrument panel (7). Secure switch (2) at face of instrument panel (7) with nut (9). For pushbutton switches, slide switch (2) in through mounting hole on instrument panel (7). Secure switch (2) at face of instrument panel (7) with nut and rubber cover assembly (8). 8-19

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business