TM10-3930-660-20
8-6.
INSTRUMENT PANELS - REPLACE (Contd)
4. INSTALL LEFT-HAND INSTRUMENT PANEL (1)
TO FRONT CONSOLB (2).
Apply Loctite 242 to threads of phillips
head screw (6).
a.
b.
Apply
(5) .
c.
d.
Lower and align panel (1) on
console (2).
Position panel (7) on panel (1).
Secure panel (7), to panel (1)
and lever housing (8) with four
phillips head screws (6).
Loctite 242 to threads of capscrews
Secure panel (1) to console (2)
with four capscrews (5).
Install new knobs (3) on shift
levers (4) by pushing knobs (3)
onto shift levers (4).
5. CONNECT NEGATIVE BATTERY CABLE,
PARA. 8-44.
8-15
|