TM10-3930-660-20
5-19. ETHER START THERMOSTAT - REPLACE (Contd)
2. CONNECT ELECTRICAL LEADS (1), (2)
AND (3).
a. Position ground wire (3), on engine
and secure with two new starwashers
(7) and capscrew (6).
b. Connect lead (1) to lead (2) by
pushing male connector (4) into
female connector (5).
3. CONNECT NEGATIVE BATTERY CABLE, PARA,
8-44.
5-42
|