TM10-3930-660-20
5-3.
FUEL SHUT-OFF SOLENOID - TEST (Contd)
Be sure starter switch is in OFF
position during step 1.
1. TEST RESISTANCE OF FUEL SHUT-OFF
SOLENOID (1).
Electrical leads (2) are connected
together with a jumper strap. DO not
remove jumper strap when disconnecting
electrical leads (2) for this test.
a.
b.
Disconnect female spade connectors
of two electrical leads R and 07
(2) from male spade connector of
solenoid (l).
Place one probe of ohmmeter at
terminal (a) of solenoid (1).
Place other probe of ohmmeter at
engine ground.
Ohmmeter should read 29.5 ohms +/- 2.5
ohms during test in step lb.
If ohms
reading is not within acceptable limits,
solenoid (1) requires replacement.
Notify direct support maintenance.
C. Connect female spade connectors of
two electrical leads R and 07 (2)
to male spade connector of solenoid
(1).
Be sure auxiliary fuel shut-off switch
is in the ON position during step 2.
2. TEST CURRENT DRAW OF FUEL SHUT-OFF
SOLENOID (1).
a. Position clamps of ammeter around
electrical leads (2)
b. Have an assistant turn the starter
switch to the ON position without
starting the engine.
Ammeter should read approximately one
ampere when starter switch is turned to
the ON position.
If reading is not
correct, solenoid (1) requires
replacement. Notify direct support
maintenance.
5-3
|