TM10-3930-660-20
5-3.
FUEL SHUT-OFF SOLENOID - TEST
This task covers:
Electrical testing of shut-off solenoid
Initial Setup
TOOlS
Tool Kit, Automotive Mechanics
Test Equipment
Ammeter
Ohmmeter
Personnel Required
Two Personnel
Equipment Condition
Vehicle parked on level ground.
Do not smoke or allow open flame or
sparks in the vicinity while working on
any part of the fuel system.
Diesel
fuel is highly flammable and can cause
injury or death if accidentally ignited.
ELECTRICAL TESTING OF FUEL SHUT-OFF
SOLENOID
The fuel shut-off solenoid is located on
the fuel injection pump and reached
through the right-hand engine access
door.
Do not attempt to remove fuel shut-off
solenoid.
If replacement is required,
refer to direct support maintenance.
5-2
|