TM10-3930-660-20
WARNING
Eye shields must be worn when cleaning with a wire
brush.
Flying rust and metal particles may cause
injury to personnel.
WARNING
Particles blown by compressed air are hazardous. Make
certain the air stream is directed away from user and
other personnel in the area.
To prevent injury, user
must wear protective goggles or face shield when using
compressed air.
b.
External Engine Cleaning.
(1)
(2)
(3)
(4)
Protect all electrical equipment that could be damaged by the steam or
moisture before steam cleaning.
Cover all openings before steam cleaning.
After cleaning, dry and apply a light coat of oil to all parts subject to
rust.
Blow out all tapped (threaded) holes with compressed air to remove dirt and
cleaning fluids.
c.
Disassembled Parts Cleaning.
(1) Place all disassembled parts in wire baskets for cleaning.
(2) Dry and cover all cleaned parts.
(3) Place parts on or in racks and hold for inspection or repair.
(4) All parts subject to rusting must be lightly oiled and wrapped.
(5) Keep all related parts and components together. Do not mix parts.
d.
Castings.
(1) Clean inner and outer surfaces of castings and all areas subject to grease
and oil with cleaning solvents.
Refer to TM9-247.
(2) Use a stiff brush to remove sludge and gum deposits.
(3) Blow out all tapped (threaded) holes with compressed air to remove dirt and
cleaning fluids.
e.
Oil Passages.
particular attention must be given to all oil passages in
castings and machined parts.
Oil passages must be clean and free of any
obstructions.
3-3
|