TM10-3930-660-10
3-8.
AIR CLEANER - SERVICE (Cont.)
Always wear safety glasses whenever
compressed air is used. Do not exceed
30 psig nozzle pressure when using
compressed air.
b. To remove remaining dust, use
compressed air under 30 psig. Blow the
air up and down the pleats from the
inside of the element. Be careful not to
damage or tear paper element.
DO NOT wash element in fuel oil, oil,
gasoline, or solvent. DO NOT use
compressed air to remove water from an
element.
c. To clean oily or sooty element, wash
thoroughly with warm water and
nonfoaming detergent. Rinse element
with clean water and allow element to
air dry. Clean outer cover and rubber
evacuator valve with soap and water.
4. INSTALL PRIMARY AIR FILTER ELEMENT.
a.
b.
c.
d.
DO NOT install element until it is dry.
Inspect element for damage. Place a
bright light inside the element and rotate
element slowly. If any rupture, holes or
damaged gaskets are discovered,
replace the element.
If a new element is to be installed,
inspect the element and gasket for
shipping and storage damage.
Install the primary filter element in the air
cleaner canister and secure with the
wing nut.
3-11
|