TM 10-3930-659-34 5-11.  TRANSMISSION GEAR PUMP REPAIR (Con’t). b.  CLEANING AND INSPECTION WARNING Dry  cleaning  solvent,  P-D-680,  is  toxic  and  flammable.    Always  wear  protective  goggles  and gloves, and use only in a well-ventilated area.  Avoid contact with skin, eyes, and clothes, and DO NOT breathe vapors.  DO NOT use near open flame or excessive heat.  The solvent’s flash point is 100°F-138°F (38°C-59°C).  If you become dizzy while using cleaning solvent, immediately get fresh air and medical help.  If solvent contacts eyes, immediately wash your eyes and get medical aid. 1. Clean all parts with dry cleaning solvent and dry with clean rags. 2. Inspect metal parts for cracks and breaks.  Replace damaged parts. 3. Clean and inspect bearings in accordance with TM 9-214. c.  ASSEMBLYI 1. Heat bearing (6) in accordance with TM 9-214. 2. Install bearing (6) on output shaft (5) with closed side toward retaining ring (7). 3. Install key (8) on output shaft (5). 4. Install new seal (9) in groove on output shaft (5). 5. Aline key (8) with groove in bore of gear pump (4) and push output shaft (5) into gear pump until bearing (6)  is firmly seated. 6. Install retaining ring (7) on output shaft (5).  Ensure that retaining ring contacts bearing (6). 7. Heat bearing (3) in accordance with TM 9-214. 8. Install bearing (3) in gear pump (4), with closed side toward retaining ring (2), until bearing is firmly seated in gear pump. 9. new preformed packing (1) and retaining ring (2) on output shaft (5).  Ensure that retaining ring contacts bearing (3). FOLLOW-ON TASKS: · Install transmission oil feed flange (see paragraph 5-10). 5-89

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business