TM 10-3930-659-34
5-9. TRANSMISSION CONTROL VALVE MAINTENANCE (Cont).
c. CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective goggles and
gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes, and DO
NOT breathe vapors. DO NOT use near open flame or excessive heat. The solvents flash point is
100°F-138°F (380C-590C). If you become dizzy while using cleaning solvent, immediately get fresh
air and medical help. If solvent contacts eyes, immediately wash your eyes and get medical aid.
1.
Clean all parts with dry cleaning solvent and dry with clean rags.
2.
Inspect metal parts for cracks and breaks. Replace damaged parts.
d. ASSEMBLY
1.
Install orifice (90) on valve block (31).
2.
Apply a light coat of lubricating oil to gearshaft valve (91).
3.
Position gearshaft valve (91) in valve block (31) and install washer (95), new shaft seal (94), washer (93), and new
retaining ring (92).
5-70
|