TM 10-3930-659-34
2-26. MULTIMETER (Cont).
CAUTION
Before performing a continuity test, always disconnect the forklift truck battery
ground cable and the circuit to be tested. Failure to follow this caution may
damage the multimeter.
(3)
Testing for Shorts. A short (or
short circuit) occurs when two circuits that
should not be connected have metal-to-metal
contact with each other. A short also occurs
when a circuit that should not touch ground
has metal-to-metal contact with ground.
TESTING FOR SHORTS
(a) Zero multimeter [see subparagraph (1)].
(b) Connect black probe (8) to one circuit and red probe (9) to either a ground or
another circuit.
(c) Read digital readout (7) and interpret the results as follows:
1. If digital readout (7) indicates 0 (zero), circuits are shorted or circuit is grounded if
TA708028 testing to ground.
2. If digital readout (7) does not indicate 0 (zero), circuits are not shorted.
2-19
3. If digital readout (7) jumps or flickers, circuits are shorted or grounded intermittently.
2-19
|