TM 10-3930-659-34
4-68.
LOCKING CONTROL VALVE REPAIR (Cont).
b.
CLEANING AND INSPECTION I
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective
goggles and gloves, and use only in a well-ventilated area. Avoid contact with
skin, eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open
flame or excessive heat. The solvent's flash point is 100°F-138°F (38°C-590°C).
If you become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts eyes, immediately wash your eyes and get
medical aid.
Compressed air used for cleaning or drying purposes, or for clearing restrictions,
should never exceed 30 psi (207 kPa). Wear protective clothing
(goggles/shield, gloves, etc.) and use caution to avoid injury to personnel.
1.
Clean metal parts with dry cleaning solvent and dry with compressed air.
2.
Inspect parts for cracks, wear, and damage. Replace damaged parts.
TA708426
4-281
|