TM 10-3930-659-34
4-54. ACCUMULATOR CHARGING (Cont).
CHARGING
WARNING
Pressure stored in accumulator is approximately 500 psi (3448 kPa). Ensure that accumulator
pressure is relieved before charging accumulators. Failure to follow this warning may result in
serious injury or death to personnel.
NOTE
It is necessary to hold boot of one brake pedal with hand while opposite brake pedal is pumped.
Movement inside boot will be felt as opposite brake pedal is pumped. Accumulator pressure is
relieved when movement stops.
Each brake pedal should be pumped a full 75 times even if no movement is felt after pumping brake
pedal several times.
1.
boot (3) of left brake pedal (4) with hand and
pump right brake pedal (1) 75 times. Release
boot.
2.
boot (2) of right brake pedal (1) with hand and
pump left brake pedal (4) 75 times. Release
boot.
4-203
|