TM 10-3930-659-34
4-54. ACCUMULATOR CHARGING.
This Task Covers: Charging
Initial Setup:
Equipment Conditions:
Materials/Parts:
Parking brake set (see TM 10-3930-659-10).
Nitrogen (Item 36, Appendix B)
Frame locking bar installed (see TM 10-3930-
One preformed packing
659-1 0).
Left transmission side guard removed (see
References:
TM 10-3930-659-20).
TM 10-3930-659-10
Tools/Test Equipment:
TM 10-3930-659-20
General mechanic's tool kit (Item 71, Appendix E)
Nitrogen accumulator charging kit (Item 13, Appendix E)
WARNING
Ensure that nitrogen accumulator charging kit pressure regulator and gage are used while
charging accumulator so that accumulator is not overcharged. Failure to follow this warning may
result in serious injury or death to personnel.
CAUTION
Accumulator must be charged with dry nitrogen only. DO NOT use air or any other gas, or
accumulator will be damaged.
NOTE
Charge accumulator slowly to avoid dislodging inlet check valve seal. Complete charging should take
three minutes or more.
Accumulators are charged the same way. One accumulator is shown.
4-202
|