TM 10-3930-659-34
4-53.
ACCUMULATOR MAINTENANCE (Cont).
b.
DISASSEMBLY
WARNING
Nitrogen pressure stored In accumulator Is approximately 500 psi (3448 kPa).
Ensure that nitrogen pressure is released before disassembling accumulators.
Failure to follow this warning may result in serious injury or death to personnel.
NOTE
Accumulators are disassembled the same way. One accumulator is illustrated.
1.
Install accumulator (7) in machinists vise with vise
jaw caps.
2.
Remove plug (11) and preformed packing (12) from
bottom of accumulator (7). Discard preformed
packing.
3.
Install nitrogen accumulator charging kit valve (10)
and hose (9) on accumulator (7). Tighten nut (13).
4.
Slowly open nitrogen accumulator charging kit valve
(10) and fully release pressure from accumulator (7).
5.
Remove nitrogen accumulator charging kit valve (10)
and hose (9) from accumulator (7).
6.
Remove snapring (17), gas end cap (16), backup ring (15), and preformed packing (14) from bottom of accumulator
(7). Discard preformed packing.